Spring Offer: Bundles + Bottle Presale | Code SPRING25

User Manual – Supersaturated Water bottle

Welcome to the official user manual for your Supersaturated Hydrogen Water Bottle. This advanced device produces highly concentrated hydrogen water and supports optional inhalation therapy. Please follow this guide for optimal use, care, and performance.

What’s in the Box?
Each Axiom H2 Supersaturated water bottle comes with everything needed for to start your hydrogen journey:

  • Hydrogen Water Bottle
  • Filter Housing
  • USB Type-C Cable
  • USB Charger
  • Inhalation Cannula
  • Inhalation Adapter Cover
  • Moisture Cap
  • 2 × Activated Carbon Filter
  • User Manual

Getting Started #

Please watch the video below before getting starter:

Before First Use #
  1. Remove the moisture cap and fill in the water bottle with filtered water.

  2. Run a 3-minute hydrogen cycle and discard the water.

  3. Repeat the cycle process 3 times.

Filling the Bottle #
  • If using filtered, distilled, or mineral water: no filter required.

  • For tap/unfiltered water: install the activated carbon filter.

Daily Use #

How to use the device #

  1. Fill the bottle to the max line (350 mL) with filtered water.
  2. Secure the top lid tightly.

  3. Press and hold the power button for 3 seconds to turn the bottle on.

  4. On the touch display, select either:

    • 3-minute cycle (standard hydrogen infusion), or

    • 20-minute cycle (supersaturated hydrogen infusion).

The bottle will automatically shut off 60 seconds after the cycle is completed.

Important: Before drinking, always release the built-up pressure by gently pressing the pressure relief valve under the top cover. This prevents damage to the O-ring and ensures safe use.

Charging #

To charge your device:

  1. Open the back cover to access the USB-C charging port.

  2. Plug in the included USB-C cable and adapter to begin charging.

    Note:

    The charging port on the bottle cap is only for the UV-C light and Schumann resonance feature. This top charger will not display charging status on the main screen.

 

Important Tips:

  • Only use the included charger and cable to ensure safe and effective charging.

  • The bottle also supports Qi wireless charging — simply place it on any compatible charging pad.

    ⚠️ Avoid placing it near water or any metal objects while charging wirelessly.

Inhalation feature #

Watch the video below for more information:

To use the inhalation feature:

  1. Fill the bottle with filtered water up to the max line (350 mL).

  2. Attach the inhalation adapter securely to the top of the bottle.

  3. Connect the cannula to the adapter.

  4. Select the 20-minute cycle on the touch display.

  5. Breathe slowly and deeply through the cannula as the hydrogen is infused.

After inhalation, the water can still be consumed.

Note: This is a complementary feature. The primary health benefits come from drinking freshly infused supersaturated hydrogen water immediately after the 20-minute cycle.

Carbon Filter #

Watch the video below for more information:

Water Type Matters

  • If you’re using purified, mineral, distilled, or boiled water, no filter is needed.

  • If you’re using tap water, insert the included filter cartridge and activated carbon filter to help protect the internal components from chlorine and sediment.

  • When traveling or using unknown water sources, we recommend using the optional activated carbon filter to reduce potential contaminants.

⚠️ Please Note:
While this bottle includes a basic filtration system, we strongly recommend using pre-filtered water whenever possible. The internal filter offers limited protection and is not designed to replace a full water purification system.

Regular use of clean, filtered water helps maintain performance, extend the life of your bottle, and preserve your warranty.

UVC Sanitation & Frequency Activation #

This model features integrated UV-C sanitation and low-frequency technology (including Schumann Resonance) to enhance water purity and support molecular structure optimization.

How to Use:

  • Press and hold the small button on the cap of the bottle to activate.

  • The UV-C and frequency cycle runs automatically for 10 minutes.

  • For best results, we recommend using this feature together with the 20-minute supersaturation cycle.

Important Notes:

  • To charge the UVC system, use the included charger.

  • The main screen will not display charging status for the cap — this is normal.

  • Do not submerge the cap in water at any time, as this can damage the UVC components and the battery.

Self-Cleaning Maintenance #

To keep your bottle performing at its best, activate the self-cleaning mode every 100 hours of use.

How to Run the Self-Clean Cycle:

  1. Fill the bottle with distilled water.

  2. Navigate to the Backwash/Self-Clean mode on the screen.

  3. Start the cycle (a 180-second ozone cleaning process).

  4. Once complete, discard the water.

Important: Only use distilled water for this process. Using mineral-rich or unfiltered water may reduce cleaning effectiveness and lead to internal buildup.

If you notice white residue or your local water has high mineral content, you may want to clean more frequently than every 100 hours.

To remove white residue, soak the electrode plates in a solution of warm water and white vinegar for 10 minutes.

Storage Instructions #

If you don’t plan to use your bottle for more than three days, it’s important to keep the PEM membrane properly hydrated to maintain performance.

To do this:

  • Detach the base from the bottle and attach the moisture cap filled with distilled water to the bottom.

  • This keeps the internal components from drying out.

  • When you’re ready to use the bottle again, simply remove the moisture cap, reassemble the device, and proceed as usual.

Avoid leaving stagnant water in the bottle or allowing the PEM membrane to dry out, as this can affect long-term performance.

Precautions #

  • Do not double cycle the 20-minute mode or run the bottle empty.
  • Always release pressure before opening the cap to avoid O-ring damage.
  • Only use the included charger and cable. 
  • Use only drinkable water.
  • Avoid gas, sediment, or hot liquids.
  • Never submerge the base or cap in water.
  • Hand wash only — do not use a dishwasher.

Contraindications #

  • Do not use the device if you have epilepsy or heart failure
  • Infants and young children under three (3) years should not use the device
  • Pregnant or nursing women should consult with their doctor prior to using the device.

Health & Safety Disclaimer

By using this device, you acknowledge and agree that Axiom H2 and its affiliates are not liable for any injury, damage, or adverse effects resulting from improper use, failure to follow instructions, or use by individuals with contraindicated medical conditions. This product is not intended to diagnose, treat, cure, or prevent any disease. Always consult a qualified healthcare provider before starting any new health-related device or protocol. Use at your own risk.

Important Safety Information #

  • Use only the included cable and plug for charging. Do not use a fast-charging plug.
  • Use only water intended for drinking inside of the bottle.
  • Do not put liquids that contain gas or sediment inside the bottle.
  • To prevent damage to the battery, circuit board, and other electronic components, do not submerge the electrolysis generator base or the bottle cap in water.
  • Do not run the electrolysis cycle consecutively with the same batch of water, as this may cause pressure buildup and damage the device.
  • Do not run the electrolysis cycle when the bottle is empty.
  • Do not use water warmer than 80°F (27°C).
  • Store the device in temperatures above 32°F (0°C) and avoid exposing it to freezing conditions.
  • Hand wash the plastic bottle with mild soap and water. Do not place any components in the dishwasher.
  • Change the water after running the backwash function.
  • The bottle must be operated with filtered water. If filtered water is unavailable, assemble the filter included with the bottle before use.
  • NEVER open before releasing the pressure valve. You can break and or lose the o- ring. If the pressure is not released from the top and you force the bottle open, the rubber O-ring might come out.
  • You’ll need to put it back correctly to ensure the bottle produces the right levels of hydrogen.
  • DO NOT double cycle the super saturated (20 minutes) cycle mode.

Warranty Information #

The hydrogen water bottle is designed to deliver up to 3,000 hours of use and comes with a one-year warranty, provided the product is maintained and used according to the guidelines.

The warranty will be void under the following circumstances:

  • Using unfiltered water or failing to use the included filter with the bottle.
  • Running the machine with water containing chlorine, which can harm the electrodes.
  • Not performing the backwash cycle after every 100 hours of runtime.
  • Double cycling the super-saturated cycle mode, as this may cause damage to the device.
  • Using improper maintenance procedures, such as opening the device without using the pressure valve, using fast charging methods or running any components through the dishwasher.

Proper maintenance and adherence to these guidelines ensure that the warranty remains valid and the bottle performs reliably for its intended lifespan. If you have questions or need assistance, please contact our customer support team at [email protected].